BRSBF - 236C0910, BAR RUST 236 MUTLI PURPOSE EPOXY(SUPDAT)

  • MSDS: BRSBF
  • Manufacturer: DEVOE COATINGS CO
  • Product Name: 236C0910, BAR RUST 236 MUTLI PURPOSE EPOXY(SUPDAT)
  • National Stock Number: 8010-00N016876
Product Identification

Product ID:236C0910, BAR RUST 236 MUTLI PURPOSE EPOXY(SUPDAT)
MSDS Date:09/21/1993
FSC:8010
NIIN:00N016876
MSDS Number: BRSBF

Responsible Party
DEVOE COATINGS CO
4000 DUPONT CIRCLE
LOUISVILLE, KY 40207
US

Emergency Phone: 800-424-9300 (CHEMTREC)

Info Phone: 502-897-9861

Cage: 1HK86

Contractor
DEVOE COATINGS CO
7600 LOUISVILLE, KY 40207-4802 US

Telephone: 502-897-9861

Cage: 1HK86

Ingredients

WHEN USED IN RESTRICTED VENT AREA, WEAR

RTECS: 9999999ZZ


APPRVD RESP WHEN FLAME CUTTING, WELDING, BRAZING &

RTECS: 9999999ZZ


STDS IN MIXING, APPLIC & CURING AREAS & TO REMOVE

RTECS: 9999999ZZ


WELDING & FLAME CUTTING ON SURFS COATED W/THIS PROD.

RTECS: 9999999ZZ


HEAVY SOLV VAPS FROM LOWER LEVS OF WORK AREA. ELIM

RTECS: 9999999ZZ


(ORAL,RAT) 5 GM/KG

Fraction By Weight: 85%

OSHA PEL N/K

ACGIH TLV: N/K


SOLVENT NAPHTHA (PETRO), LIGHT AROMATIC; (NAPHTHA, LIGHT

CAS: 64742-95-6

RTECS: WF3400000

Fraction By Weight: 5%

OSHA PEL N/K

ACGIH TLV: 100 PPM (MFR)


2.14.

CAS: 110-43-0

RTECS: MJ5075000

Fraction By Weight: 10%

OSHA PEL 100 PPM

ACGIH TLV: 50 PPM


147.37 (GRAMS/LITER)

RTECS: 9999999VO

OSHA PEL N/K

ACGIH TLV: N/K


APPARENT. OBTAIN MEDICAL ATTENTION.

RTECS: 9999999ZZ


CONSULT PHYS IMMED.

RTECS: 9999999ZZ


NON-SPK TOOLS. STORE IN CLSD CNTNR UNTIL

RTECS: 9999999ZZ


IS PART OF TWO COMPONENT PROD, THEN MIX OF BASE

RTECS: 9999999ZZ


THIS

RTECS: 9999999ZZ


BIRTH DEFECTS, OR OTHER REPRODUCTIVE HARM

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:SEE INGREDIENTS
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INHALATION:IRRITATION OF
RESPIRATORY TRACT; HEADACHE, NAUSEA, DIZZINESS, WEAKNESS & FATIGUE.
EXTREME EXPOSURE CAN RESULT IN UNCONSCIOUSNESS & EVEN RESPIRATORY
ARREST. SKIN/EYE:CAUSE EYE & SKIN I RRITATION. MAY BE HARMFUL IF
ABSORBED THRU SKIN. CAUSE SKIN BURNS. INGESTION:CAN CAUSE STOMACH
AND/OR(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:INTESTINAL IRRITATION, NAUSEA,
VOMITING AND DIARRHEA. CHRONIC:REPORTS HAVE ASSOCIATED REPEATED &
PROLONGED OCCUPATION OVEREXPOSURE TO SOLVENTS W/PERMANENT BRAIN &
NERVOUS SYSTEM DAMAGE. PROLO NGED OR REPEATED BREATHING OR SPRAY
MIST AND/OR SANDING DUST OVER PERIOD OF YEARS MAY CAUSE DUST
DISEASE OF THE LUNGS.
Medical Cond Aggravated by Exposure:NONE, WHEN USED IN ACCORDANCE WITH
SAFE HANDLING AND USE INFORMATION.

First Aid

First Aid:INHAL:IF YOU EXPERIENCE DFCLTY IN BRTHG, LEAVE AREA TO OBTAIN
FRESH AIR. IF CONTINUED DFCLTY IS EXPERIENCED, SUMMON MED
ASSISTANCE IMMED. IF BRTHG CEASES, RESTORE USING APPRVD CPR
TECHNIQUES & SUMMON MED HELP IMMED. EYES:FLUSH IMMED W/LG AMTS OF
WATER FOR @ LEAST 15 MINS. GE MED ASSISTANCE. SKIN:WASH AFFECTED
AREAS W/SOAP & WATER. REMOVE SOILED CLTHG. GET MED ASSISTANCE IF
IRRIT PERSISTS. (ING 8)

Fire Fighting

Flash Point Method:SCC
Flash Point:100F,38C
Lower Limits:1%
Extinguishing Media:CO*2 DRY CHEMICAL, FOAM, OR OTHER NATIONAL FIRE
PROT ASSOC (NFPA) APPRVD METH FOR TREATING CLASS B FIRE.
Fire Fighting Procedures:NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP .
WATER SPRAY MAY BE INEFTIVE. IF WATER IS USED, FOG NOZZ PREF. IF
EXPOS TO FIRE/EXTREME HEAT, WATER (SUPDAT)
Unusual Fire/Explosion Hazard:KEEP CNTNRS TIGHTLY CLSD. ISOLATE FROM
HEAT, ELEC EQUIP, SPK & FLAME. DUE TO PRESS BUILD-UP, CLSD CNTNRS
EXPOS TO EXTREME HEAT MAY EXPLODE. NEVER USE (SUPDAT)

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNIT (FLAMES, HOT
SURFS, & ELEC, STATIC/FRICTIONAL SPARKS). PVNT BRTHG OF VAPS. VENT
AREA. BEFORE ATTEMTPING CLEAN-UP, REFER TO HAZ CAUTION INFO IN
OTHER SECTIONS OF MSDS. CNTN SPILLED MATL & REMOVE W/INERT ABSORB
& (ING 7)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP AWAY FROM HEAT, SPKS & FLAMES. DO
NOT SMOKE. PVNT BUILD-UP OF VAPS BY MAINTAINING CONTINUOUS FLOW OF
FRESH AIR.
Other Precautions:DO NOT STORE ABOVE 120F/NEAR FIRE OR OPEN FLAME.
STORE LG QTYS IN BUILDINGS TO COMPLY W/OSHA 1910.106. KEEP CNTNR
CLSD WHEN NOT IN USE. DO NOT TRANSFER CONTENTS TO BOTTLES/OTHER
UNLBLD CNTNRS. DO NOT REUSE EMPTY CNTNRS. IF THIS MATL (ING 8)

Exposure Controls

Respiratory Protection:DO NOT BREATHE VAPS, SPRAY MIST/SANDING DUST.
WHEN SPRAY APPLIED IN OUTDOOR/OPEN AREAS, & DURING SANDING/GRINDING
OPERATIONS, USE NIOSH/MSHA APPRVD MECH FILTER RESP TO REMOVE SOLID
AIRBORNE PARTICLES OF OVERSPRAY & SANDING DUST. (ING 11)
Ventilation:PROVIDE GEN DILUTION/LOC EXHAUST VENT IN VOL & PATTERN TO
KEEP AIR CONTAM CONC BELOW CURRENT APPLIC SFTY & HLTH (ING 13)
Protective Gloves:SOLVENT RESISTANT GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:SOLV IMPERMEABLE CLTHG & BOOTS. ANSI APPRVD
EMERGENCY EYE WASH & DELUGE SHOWER .
Work Hygienic Practices:REMOVE & WASH SOILED CLTHG BEFORE REUSE. WASH
HANDS BEFORE EATING OR SMOKING.
Supplemental Safety and Health
MFR TRADE NAME/PART NO:COATING CLEAR CONVERTER. FIRE FIGHT PROC:SHOULD
BE USED TO COOL CLSD CNTNRS & PVNT PRESS BUILD UP/POSS AUTO-IGNIT.
EXPLO HAZ:WELDING/CUTTING TORCH ON/NEAR CNTNR (EVEN EMTPY) AS
PROD/ITS RESIDUE MAY IGNITE. DURING EMER CNDTNS OVEREXP TO DECOMP
PROD MAY CAUSE HLTH HAZ. SYMPS MAY NOT BE IMMED(ING 7)

Chemical Properties

HCC:F4
Boiling Pt:B.P. Text:>300F,>149C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:0.98
Evaporation Rate & Reference:SLOWER THAN ETHER
Solubility in Water:NOT KNOWN
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:17.60

Stability

Stability Indicator/Materials to Avoid:YES
AVOID CONTACT WITH STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:MAY CAUSE TOXIC FUMES WHEN HEATED TO
DECOMPOSITION. FUMES MAY CONTAIN CARBON MONOXIDE.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL REGULATIONS. INCINERATE ONLY IN APPROVED FACILTIY. DO NOT
INCINERATE CLOSED CONTAINERS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.